Home » Pressure » Fluke 68 Adjustable Infrared Thermometer
Fluke 68 Adjustable Infrared Thermometer




The Fluke 68 non-contact thermometer
are the ideal professional diagnostic tools for HVAC
technicians performing room balance checks, electricians
evaluating electrical connections and auto mechanics
diagnosing catalytic converters.
This handheld portable
tool enables professionals to research heating and ventilation
problems, monitor the status of electrical motors
and electrical panels and diagnose car malfunctions with
ease.
It measures surface temperatures, helping to quickly locate potential blockages or malfunctioning systems reducing work time and improving performance.
The Bad:
The Bottom Line:
Full Review
- Laser guided sighting system for easy targeting with 1 % accuracy
- 12-point data logging
- Advanced optics to measure smaller targets at greater distances
- Adjustable emissivity for more accurate temperature measurements
- Selectable MAX, MIN, DIF and AVG functions that display values instantly with Hi/Lo Alarm
- Expanded measurement range up to 760 °C (1400 °F)
- Temperature range °C -32 to 760 °C (-25 to 1400 °F)
- Accuracy -32 to -26 °C (-25 to -15 °F): ±3 °C (±5 °F)
- (assumes ambient -26 to -18 °C (-15 to 0 °F): ±2.5 °C (±4 °F)
- operating temperature -18 to 23 °C (0 to 73 °F): ±2 °C (±3 °F)
- of 23 °C [73 °F]) For targets above 23 °C (73 °F): ±1 % or reading
- or ±1 °C (±2 °F), whichever is greater
- Repeatability ±0.5 % or ² ±1 °C (±2 °F), whichever is greater
- Response time ² 0.5 second (95 % of reading)
- Spectral response 8 to 14 µm
- Emissivity Digitally adjustable emissivity (from 0.1 to 1.0 by 0.01)
- Ambient operating temp. 0 to 50 °C (32 to 120 °F)
- Relative humidity 10 to 90 % RH non-condensing,
- at <30 °C (86 °F) ambient
- Storage temperature -20 to 60 °C (-13 to 158 °F) without battery
- Dimensions 200 x 160 x 55 mm (8 x 6 x 2 in.)
- Weight 320 g (11 oz.)
- Power 9 V alkaline or NiCd battery
- Batter life (alkaline) 20 hours with laser and backlight on 50 %
- 40 hours with laser and backlight off
- Laser sighting (Class II) Offset single point laser point
- Typical distance to target 8 m (25 ft.)
- Distance to Spot (D:S) 50:1 at focus point
- MIN, MAX, AVG, DIF
- Temperature display •
- Data logging 12 points
- Probe jack •
- Display hold (7 seconds) •
- Hi/Low alarm •
- LCD backlit •
- Temperature display °C or °F selectable
- Display resolution 0.1 °C (0.1 °F)
- Hard carrying case •
- Locking trigger •
- Tripod mounting 6.35 mm (.25 in.) 20 UNC threading
- Warranty 1 year


Yes! Available up to 



