Designed by electricians. Engineered by Fluke.
The Fluke 116 HVAC Multimeter features temperature and microamps measurements useful for heating, ventilation, air conditioning and refrigeration (HVAC/R) technicians. The Fluke 116 is a compact true-rms meter and has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors.
The Fluke 116 also, has dual impedance capability: incorporating both regular high impedance test capabilities and low impedance functions for detecting ghost voltages, just switch to the Auto-V/LoZ (low impedance) test setting to whether measurement is a ghost voltage.
- Auto-V stands for automatic volts. This feature automatically determines whether the measured signal is ac voltage or dc voltage, selects the correct function and range, and displays the correct information.
- LoZ stands for Low Impedance (Z). This feature presents a low impedance input to the circuit under test. This reduces the possibility of false readings due to ghost voltages and improves accuracy when testing to determine absence or presence of voltage.
Also check out the
Fluke 114 Electrical Multimeter, the
Fluke 115 Multimeter, and the
Fluke 117, the Electrician’s Multimeter with Non-contact voltage.
What's Included:
- 4 mm silicone test lead set
- 80BK Integrated Temperature probe
- Holster
- Installed 9 V battery
- User manual
| Specifications |
| Maximum voltage between any terminal and earth ground | |
| Surge protection |
|
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
|
| Display |
| Digital: |
6,000 counts, updates 4 per second |
|
| Bar graph |
|
33 segments, updates 32 per second |
|
| Operating Temperature | |
| Storage Temperature | |
| Battery type |
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
| Battery Life |
|
400 hours typical, without backlight |
|
| Accuracy Specifications |
| DC millivolts |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
± ([% of reading] + [counts]): 2.0% + 3 |
|
| DC volts |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.00 V / 0.1 V |
|
| Auto volts |
| Range: |
600.0 V |
| Resolution: |
0.1 V |
| Accuracy: |
2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
|
| AC millivolts1 true-rms |
| Range: |
600.0 mV |
| Resolution: |
0.1 mV |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
|
| AC volts1 true-rms |
| Range/Resolution: |
6.000 V / 0.001 V |
| Range/Resolution: |
60.00 V / 0.01 V |
| Range/Resolution: |
600.0 V / 0.1 V |
| Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
|
| Continuity |
| Range: |
600 Ω |
| Resolution: |
1 Ω |
| Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
|
| Ohms |
| Range/Resolution: |
600.0 Ω / 0.1 Ω |
| Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
| Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
| Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
| Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
| Accuracy: |
0.9 % + 1 |
| Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
| Accuracy: |
1.5 % + 2 |
|
| Diode Test |
| Range/Resolution: |
2.000 V / 0.001 V |
| Accuracy: |
0.9% + 2 |
|
| Capacitance |
| Range/Resolution: |
1000 nF / 1 nF |
| Range/Resolution: |
10.00 μF / 0.01 μF |
| Range/Resolution: |
100.0 μF / 0.1 μF |
| Range/Resolution: |
9999 μF / 1 μF |
| Range/Resolution: |
100 μF to 1000 μF |
| Accuracy: |
1.9% + 2 |
| Range/Resolution: |
> 1000 μF |
| Accuracy: |
5% + 20% |
|
| LoZ capacitance |
| Range: |
1 nF to 500 μF |
| Accuracy: |
10% + 2 typical |
|
| Temperature2 (Type-K thermocouple) |
| Range/Resolution: |
-40 °C to 400 °C / 0.1 °C |
| Accuracy: |
1% + 102 |
| Range/Resolution: |
-40 °F to 752 °C / 0.2 °F |
| Accuracy: |
1% + 182 |
|
| AC μamps true-rms (45 Hz to 500 Hz) |
| Range/Resolution: |
600.0 μA / 0.1 μA |
| Accuracy: |
1.0% + 2 |
|
| DC μamps |
| Range/Resolution: |
600.0 μA / 0.1 μA |
| Accuracy: |
1.0% + 2 |
|
| Hz (V or A input)2 |
| Range/Resolution: |
99.99 Hz / 0.01 Hz |
| Range/Resolution: |
999.99 Hz / 0.1 Hz |
| Range/Resolution: |
9.999 Hz / 0.001 Hz |
| Range/Resolution: |
50.00 Hz / 0.01 Hz |
| Accuracy: |
0.1% + 2 |
|
Notes:
1) All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified,
it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected
from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full
scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.
| Mechanical & General Specifications |
| Size |
| Height: |
27.62 cm (10.875") |
| Length: |
15.875 cm (6.25") |
| Width: |
5.6 cm (2.203") |
|
| Weight | |
| Warranty | |
No user reviews available.