Home » MadgeTech Volt101 Voltage Data Logger
MadgeTech Volt101 Voltage Data Logger




The MadgeTech Volt101 Voltage Data Logger is geared toward helping users measure and record low-level voltages with high accuracy and resolution. The device records 16 bits of resolution, ideal for accurately measuring battery voltages, sensor monitoring, photovoltiac studies, measuring thermopiles as well as other common voltage sources. Records time and date stamped DC voltage data.
Features user-programmable Engineering Units and offset/gain calculations so input voltages can be scaled to proper units being measured. For example, a flow rate sensor with a voltage output can be displayed as flow rate in the software graph and data. This is a unique and very useful feature for presentations.
Four different voltage ranges are available. Single channel, screw terminal input (±100mV model features differential input capability).
Reminder: An IFC cable is required for operation of data loggers!
APPLICATIONS:
Features user-programmable Engineering Units and offset/gain calculations so input voltages can be scaled to proper units being measured. For example, a flow rate sensor with a voltage output can be displayed as flow rate in the software graph and data. This is a unique and very useful feature for presentations.
Four different voltage ranges are available. Single channel, screw terminal input (±100mV model features differential input capability).
Reminder: An IFC cable is required for operation of data loggers!
APPLICATIONS:
- Low level signal monitoring
- Battery studies
- Power supply monitoring
- Process plants
- Medical/Pharmaceutical
- Research and development
- Environmental studies
- Replace costly strip chart recorders
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- Programmable engineering units
- Multiple input ranges available
- Real-time operation
- Programmable start time
- Reusable
- Miniature size
- Low cost
- User-friendly
- CE compliant
| Range | ±100mVDC | 0 to 2.5VDC | 0 to 15VDC | 0 to 30VDC |
| Accuracy | ±0.01%FSR @ 25°C | ±0.01%FSR @ 25°C | ±0.10%FSR @ 25°C | ±0.10%FSR @ 25°C |
| Resolution | 5μVDC | 0.1mVDC | 0.5mVDC | 1.0mVDC |
|
Memory:
|
32,767
|
|||||||||
|
Sample Rate:
|
1 second up to 12 hours
|
|||||||||
|
LED Indicator:
|
Red
|
|||||||||
|
Channels:
|
1
|
|||||||||
|
Required Interface Package:
|
IFC110
|
|||||||||
|
Baud Rate:
|
2,400
|
|||||||||
|
Typical Battery Life:
|
1 year
|
|||||||||
|
Operating Environment:
|
-40~+80°C, 0~95%RH non-condensing
|
|||||||||
|
Material:
|
ABS plastic
|
|||||||||
|
Dimensions:
|
1.4" x 2.5" x 0.6" (36mm x 64mm x 16mm)
|
|||||||||
|
CE Approval:
|
Yes
|
|||||||||
|
Weight:
|
0.9oz.
|
|||||||||
No user reviews available.