The Lascar EL-USB-1-RCG is a Rechargeable USB temperature data logger with a measurement
range of -20 to +60°C (-4 to +140°F). The data logger can store up to 32,510 readings and is supplied with a lithium-ion
battery which allows for logging for up to 1 month.
The glass window and stainless steel 316 assembly provide protection from corrosion, impact and water ingress to IP67 / NEMA 4X, which keeps this Lascar USB data logger protected from the environment.
What's Included:
The glass window and stainless steel 316 assembly provide protection from corrosion, impact and water ingress to IP67 / NEMA 4X, which keeps this Lascar USB data logger protected from the environment.
What's Included:
- Lascar EL-USB-1-RCG
- USB cable
- Mini-CD
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- -20 to +60°C (-4 to +140°F) measurement range
- Stainless steel (316 grade) case
- Environmental protection to IP67
- Rechargeable lithium-ion battery
- Bi-color status LEDs behind protective glass window
- Mini-USB interface for set-up and data download
- User programmable alarm thresholds
- Immediate and delayed start logging
- Supplied with Windows control software and Type A to Mini B USB cable
| Specifications | Minimum | Typical | Maximum | Unit |
| Measurement range | -20 (-4) | +60 (+140) | °C (°F) | |
| Accuracy (overall error) | ±1 (2) | °C (°F) | ||
| Internal resolution | 0.1 (0.2) | °C (°F) | ||
| Logging rate | every 1s | every 12hr | - | |
| Recharging time | 5 | Hours | ||
| Operating temperature range | -20 (-4) | +60 (+140) | °C (°F) | |
| Charging temperature range | 0 (+32) | +20 (+68) | +45 (+113) | °C (°F) |
| Lithium-ion Battery Life | 1* | 4** | Weeks |
* @ -20°C (-4°F), 1 second logging rate
** @ 20°C (68°F), 1 minutes logging rate
EL-WIN-USB (Data Logger Control Software)

Lascar’s EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control so ftware runs under Windows 2000, XP (Home and Professional Editions) & Vista (32-bit). The software is used to set-up the data logger as wel l as download, graph and export data to Excel.
The software allows the following parameters to be configured:
Download EL-WIN-USB (Data Logger Control Software)
To download and install Lascar's EL-WIN-USB software take the following steps:
1. Download El-WIN-USB Click here
2. When prompted about whether you wish to open or save the file choose 'Save'.
3. Select a location to save the zip file to and click 'Save'.
4. When the download is complete, right-click on the .zip file and choose 'Extract All'
5. This will open the 'Compressed (zipped) Folders Extraction Wizard'. Click 'Next' and then select a location to unzip the file to. Click 'Next' again to begin the extraction.
6. Click 'Finish' to close the wizard.
7. To begin installation, navigate to the folder where the download file was extracted to and double-click 'Setup.exe'. This will open the 'EasyLog USB Setup Wizard'.
HINT : A pdf titled 'EL-USB Installation and Operation Guide.pdf' is included with the download and gives more detailed instructions on navigating the 'EasyLog USB Setup Wizard'.
8. Before using your data logger with the software you must first install the Windows driver. To do this, insert your data logger (with battery installed) into a free USB port on your computer.
9. This will open the 'Found New Hardware Wizard'.
10. If asked if you wish to connect to 'Windows Update' choose 'No, not this time' and click 'Next'.
11. Choose 'Install from a list or a specific location (advanced)'.
12. Ensure 'Search for the best driver in these locations' is selected, put a 'tick' in the 'Select this location in the search' option and click 'Browse'.
13. Navigate to the location where the download file was extracted to and click 'Next'.
14. If prompted by a Microsoft warning screen click 'Continue Anyway'.
HINT : This is a feature of Windows XP. Selecting 'Continue Anyway' will not harm your computer in any way.
15. Click 'Finish'. You are now ready to begin using your Lascar EL-USB data logger.

Lascar’s EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control so ftware runs under Windows 2000, XP (Home and Professional Editions) & Vista (32-bit). The software is used to set-up the data logger as wel l as download, graph and export data to Excel.
The software allows the following parameters to be configured:
- Logger name
- °C, °F
- Logging rate (10s, 1m, 5m, 30m, 1hr, 6hr, 12hr)
- High and low alarms
- Immediate, delayed and push-to-start logging
- Display o, on for 30 seconds after button press, or permanently on
- Data rollover (allows unlimited logging periods by overwriting the oldest data when the memory is full)
Download EL-WIN-USB (Data Logger Control Software)
To download and install Lascar's EL-WIN-USB software take the following steps:
1. Download El-WIN-USB Click here
2. When prompted about whether you wish to open or save the file choose 'Save'.
3. Select a location to save the zip file to and click 'Save'.
4. When the download is complete, right-click on the .zip file and choose 'Extract All'
5. This will open the 'Compressed (zipped) Folders Extraction Wizard'. Click 'Next' and then select a location to unzip the file to. Click 'Next' again to begin the extraction.
6. Click 'Finish' to close the wizard.
7. To begin installation, navigate to the folder where the download file was extracted to and double-click 'Setup.exe'. This will open the 'EasyLog USB Setup Wizard'.
HINT : A pdf titled 'EL-USB Installation and Operation Guide.pdf' is included with the download and gives more detailed instructions on navigating the 'EasyLog USB Setup Wizard'.
8. Before using your data logger with the software you must first install the Windows driver. To do this, insert your data logger (with battery installed) into a free USB port on your computer.
9. This will open the 'Found New Hardware Wizard'.
10. If asked if you wish to connect to 'Windows Update' choose 'No, not this time' and click 'Next'.
11. Choose 'Install from a list or a specific location (advanced)'.
12. Ensure 'Search for the best driver in these locations' is selected, put a 'tick' in the 'Select this location in the search' option and click 'Browse'.
13. Navigate to the location where the download file was extracted to and click 'Next'.
14. If prompted by a Microsoft warning screen click 'Continue Anyway'.
HINT : This is a feature of Windows XP. Selecting 'Continue Anyway' will not harm your computer in any way.
15. Click 'Finish'. You are now ready to begin using your Lascar EL-USB data logger.
Product brochures
No user reviews available.