1.888.610.7664

info@DataLoggerStore.com

Chat Live

Yopto star rating

Customer Rating: 5.0/5 Stars

Lascar EL-GFX-DTC Temperature Data Logger with LCD Screen
Model: EL-GFX-DTC

Dual channel thermocouple data logger with LCD screen that displays real-time readings. Compatible with K, J and T Type thermocouples.

Need a quote?

$156.33 USD


was $185.00

Availability: 1 to 2 Weeks






Dual Channel Thermocouple Data Logger with Graphic Screen

The EL-GFX-DTC standalone USB data logger measures and stores over 250,000 temperature readings from two J, K, or T-type thermocouple inputs at a resolution of 0.1°C. Using the Windows control software (available as a free-download), users can quickly set up the data logger and view downloaded data by connecting the device to the PC's USB port using the supplied cable.

The data logger features a high-contrast graphic LCD and three-input buttons which allows users to start, stop and restart the data logger using on-screen menus. This menu also provides real-time analysis of data either as a data summary (showing highest & lowest readings and alarm conditions) or as a graph that updates as new data is added. Multiple data logging sessions can be stored on the device ready for upload to a PC at a later date.

The two replaceable ½AA batteries typically allow logging for up to four months.


Features:

  • Dual channel, compatible with K, J and T type Thermocouples
  • Logging rates between 1 second and 1 hour
  • Immediate, delayed, push-button or temperature triggered start mode
  • Graphic LCD shows real-time readings, graph and current status
  • Stores over 250,000 readings
  • Calibration certificate available

Applications:

The EL-GFX-DTC is suitable for a wide variety of applications, these include:

  • Pharmaceutical fridge monitoring
  • Transportation
  • Food & drink
  • Building & site monitoring
  • HVAC

Specifications:

Specification Min. Typ. Max. Unit
Probe measurement range K-type -200 (+328)   +1350 (+2462) °C (°F)
J-type -200 (+328)   +1190 (+2174) °C (°F)
T-type -200 (+328)   +390 (734) °C (°F)
Internal resolution   0.1 (0.1)*   °C (°F)
Accuracy (overall error)   ±0.5 (±0.9)**   °C (°F)
Logging rate Every 1 second   Every 1 hour Time
Operating temperature range* -10 (-14)   +40 (+104) °C (°F)
2 x ½AA 3.6V Lithium Battery Life   4†   Months

* Above 999.9°C/F display becomes 1°C. Internal resolution remains at 0.1°C/F.
** Quoted accuracy is for the data logger only when measuring within the specified operating temperature. Thermocouple error is not included and should also be taken into consideration.
*** Operating temperature applies to the data logger module only. Please consult the probe manufacturer for operating temperature of thermocouple.
† At 25°C and 10 minute logging rate with no alarm LEDs or sounder and minimal LCD use.

Click here for complete specifications on the Lascar EL-GFX-DTC

What's included with the Lascar EL-GFX-DTC

  • Lascar EL-GFX-DTC Temperature Data Logger with LCD Screen
  • Software:

    Set up and data download of our EasyLog data loggers is enabled by our EL-WIN-USB software. It is compatible with 32-bit and 64-bit versions of Windows XP, Vista, 7 & 8.

    Download the latest version of the software below. Please note, the software is not compatible with Mac or Linux.

    Download Software

    Review the Lascar EL-GFX-DTC

    " data-description="Dual channel thermocouple data logger with LCD screen that displays real-time readings. Compatible with K, J and T Type thermocouples.">
    comments powered by Disqus